rMIX DN25s 2x4 RH 1-a

Item no. 001 263 Return flow utilisation
For highly efficient use of the return flow of an unmixed high-temperature circuit in a mixed low-temperature circuit at a condensing boiler, a stratified tank or a heat transfer station.

Recommended accessories

								

DÜV DN15 2x2 MUL-Set R

001345
								

ISO KuHV DN25s G1½(i)xRp1

996085

Further information?

Further questions?

Contact technical support
					

Configure product variant

Nominal width

DN25s

Performance class

Direct heating circuit (HT):
Kvs = 11.9 • V'max[100mbar] = 3.8m³/h
Q'max[20K] = 88kW
Mixing circuit (LT):
Kvs = 12.9 • V'max[100mbar] = 4.1m³/h
Q'max[10K] = 48kW

Flow direction producer

Flow direction Producer Right

Product documentation

Assembly instructions

Assembly instructions: For specialist partners only.
Please log in here or register here

Actuator multi-way mixer: For specialist partners only.
Please log in here or register here

Spare parts drawing

Spare parts drawing For specialist partners only.
Please log in here or register here

Data sheet

001263_DBL_2019-12-12.pdf

GAEB

001263.D81

Tender text

Baunach article master data Version: 19.11.24

BAFA funding opportunity within the scope of heating system optimisation by replacing heating circulating pumps with high-efficiency circulating pumps.

rendeMIX multi-port mixing manifold with 3/3-way tangential mixing valve DN25×G1½(a) MsGuss (adapter green), plug and cover Ms58

For highly efficient use of the return flow of an unmixed high-temperature circuit in a mixed low-temperature circuit at a condensing boiler, a stratified tank or a heat transfer station.

Actuator EMS 240, 230V~ 50Hz 3.5VA 3-point signal, 5Nm (240h), 240°, 93s

Dual circuit manifold assembly with 2 connections to the heat source and 4 connections to the heat sinks, CuØ35×1, DN32×G1½(a) flat, pipe spacing 100mm.

3 integrated gravity brakes/backflow preventer, Dp10mbar

Direct heating circuit (HT): Kvs = 11.9 - V'max[100mbar] = 3.8m³/h - Q'max[20K] = 88kW - Mixed heating circuit (LT): Kvs = 12.9 - V'max[100mbar] = 4.1m³/h - Q'max[10K] = 48kW - Leakage rate < 0,1%

6 Thermometers 0-120°C, Ø63mm, soldering sleeves Ms58

6 ball valve screw connections, DN25s passage, PN20, G1½(i)×Rp1 flat-sealing, stuffing box, spindle with aluminium T-handle

Insulating moulded tray EPP 40g/l, black, 450×450mm, quick assembly kit

With pump flange G1½(i) for pump DN25 on heat generator flow (1)

Assembly includes ONE pump balancing piece - PAS L180 - with G1½(a)×G1½(i) fittings for balancing one pump DN25, length 180mm, insulated (part no.: 001 338).

With built-in high-efficiency Grundfos UPM3 pump, DN25, 130mm, H 5-6mWS, 230V~ 50Hz, 2m connection cable, EEI < 0,2

Model DN 25 - strong version, PN 10bar, Tmax 120°C

Performance data

Direct heating circuit (HT): Kvs = 11.9 - V'max[100mbar] = 3.8m³/h - Q'max[20K] = 88kW - Mixed heating circuit (LT): Kvs = 12.9 - V'max[100mbar] = 4.1m³/h - Q'max[10K] = 48kW - Leakage rate < 0,1%