rSYS DN25 2x4 LT 1-a

Item no. 001 510 Return flow utilisation
TWIN assembly for the expansion of a rendeMIX 2x4 assembly by an additional low-temperature mixing circuit with return use of the high-temperature circuit and highly efficient operation of a system separation via flow control

Accessories needed

								

ST DN25 AD100 P40 RR 5

001009
								

ST DN25 AD100 P40 RR

001007

Further information?

Further questions?

Contact technical support
					

Configure product variant

Nominal width

DN25

Performance class

Downstream assembly (HT):
Kvs = 6.5 • V'max[100mbar] = 2.1m³/h
Q'max[20K] = 49kW
Additional mixing circuit (NT) with ST DN25:
Kvs = 5.7 • V'max[100mbar] = 1.8m³/h
Q'max[10K] = 21kW

Flow direction producer

Flow direction Producer Left

Pump flange

Product documentation

Assembly instructions

Assembly instructions: For specialist partners only.
Please log in here or register here

Actuator multi-way mixer: For specialist partners only.
Please log in here or register here

Spare parts drawing

Spare parts drawing For specialist partners only.
Please log in here or register here

Data sheet

001510_DBL_2020-09-17.pdf

GAEB

001510.D81

Tender text

Baunach article master data Version: 19.11.24

BAFA funding opportunity within the scope of heating system optimisation by replacing heating circulating pumps with high-efficiency circulating pumps.

rendeMIX multi-port mixing manifold with 3/2-way tangential mixing valve DN25×G1½(a) MsGuss (adapter red), plug and cover Ms58

TWIN assembly for the expansion of a rendeMIX 2x4 assembly by an additional low-temperature mixing circuit with return use of the high-temperature circuit and highly efficient operation of a system separation via flow control

Actuator EMS 240, 230V~ 50Hz 3.5VA 3-point signal, 5Nm (240h), 240°, 93s

Dual circuit manifold assembly with 2 connections to the heat source and 4 connections to the heat sinks, CuØ35×1, DN32×G1½(a) flat, pipe spacing 100mm.

1 integrated gravity brake/backflow preventer, Dp10mbar

Downstream assembly (HT): Kvs = 6.5 - V'max[100mbar] = 2.1m³/h - Q'max[20K] = 49kW - Additional mixing circuit (LT) with ST DN25: Kvs = 5.7 - V'max[100mbar] = 1.8m³/h - Q'max[10K] = 21kW - Leakage rate < 0,1%

4 thermometers 0-120°C, Ø63mm, soldering sleeves Ms58

2 ball valve screw connections, DN25 passage, PN32, G1½(i)×Rp1 flat-sealing, stuffing box, sealing hole, spindle with aluminium wing handle

Insulating moulded tray EPP 40g/l, black, 450×450mm, quick assembly kit

With pump flange G1½(i) for pump DN25 on heat generator flow (1)

Assembly does NOT include pump compensator - PAS L180 (Part No.: 001 338)

With built-in high-efficiency Grundfos UPM3 pump, DN25, 130mm, H 5-6mWS, 230V~ 50Hz, 2m connection cable, EEI < 0,2

Model DN 25 - light version, PN 10bar, Tmax 120°C

ATTENTION: CANNOT BE USED WITHOUT SYSTEM SEPARATION!

Performance data

Downstream assembly (HT): Kvs = 6.5 - V'max[100mbar] = 2.1m³/h - Q'max[20K] = 49kW - Additional mixing circuit (LT) with ST DN25: Kvs = 5.7 - V'max[100mbar] = 1.8m³/h - Q'max[10K] = 21kW - Leakage rate < 0,1%

Baunach