rMIX DN25s 2x4+3mix R 35

Item no. 001 783 Return flow utilisation
For discharging a stratified tank in a mixed low-temperature circuit (2nd mixed circuit) with highly efficient use of the return flow of a mixed high-temperature circuit (1st mixed circuit) with the lowest possible return flow temperature.

Recommended accessories

								

ISO KuHV DN25s G1½(i)xRp1

996085

Further information?

Further questions?

Contact technical support
					

Configure product variant

Nominal width

DN25s

Flow direction producer

Flow direction Producer Right

Pump flange

on the heating (3) and mixing circuit flow (5)

Product documentation

Assembly instructions

Assembly instructions: For specialist partners only.
Please log in here or register here

Actuator multi-way mixer: For specialist partners only.
Please log in here or register here

Actuator three-way mixer: For specialist partners only.
Please log in here or register here

Spare parts drawing

Spare parts drawing For specialist partners only.
Please log in here or register here

Data sheet

001783_DBL_2021-12-21.pdf

GAEB

001783.D81

Tender text

Baunach article master data Version: 19.11.24

BAFA funding opportunity as part of heating system optimisation through hydraulic balancing and installation of separate control technology

rendeMIX multi-port mixing manifold with 3/3-way tangential mixing valve DN25×G1½(a) MsGuss (red adapter) and 3-way mixing valve DN32×G1½(a) Ms58, plug and cover Ms58

For discharging a stratified tank in a mixed low-temperature circuit (2nd mixed circuit) with highly efficient use of the return flow of a mixed high-temperature circuit (1st mixed circuit) with the lowest possible return flow temperature.

1st mixing circuit: EMS 90-3P actuator, 230V~ 50Hz 3.5VA 3-point signal, 5Nm (240h), 90°, 70s, grey adapter. 2nd mixing circuit: EMS 240 actuator, 230V~ 50Hz 3.5VA 3-point signal, 5Nm (240h), 240°, 93s

Dual circuit manifold assembly with 2 connections to the heat source and 4 connections to the heat sinks, CuØ35×1, DN32×G1½(a) flat, pipe spacing 100mm.

3 integrated gravity brakes/backflow preventer, Dp10mbar

1st mixing circuit (HT): Kvs = 13.3 - V'max[100mbar] = 4.2m³/h - Q'max[20K] = 98kW - leakage rate < 0.1% - 2nd mixing circuit (NT): Kvs = 12.9 • V'max[100mbar] = 4.1m³/h • Q'max[10K] = 48kW • Leakage rate < 0,1%

6 Thermometers 0-120°C, Ø63mm, soldering sleeves Ms58

6 ball valve screw connections, DN25s passage, PN20, G1½(i)×Rp1 flat-sealing, stuffing box, spindle with aluminium T-handle

Insulating moulded tray EPP 40g/l, black, 450×450mm, quick assembly kit

With pump flanges G1½(i) for pumps DN25 on the 1st mixed high (3) and on the 2nd mixed low temperature circuit flow (5).

Assembly includes TWO pump balancers - PAS L180 - with G1½(a)×G1½(i) fittings for balancing a pump DN25, length 180mm, insulated (part no.: 001 338).

Assembly does not contain a pump

Model DN 25 - strong version, PN 10bar, Tmax 120°C

Performance data

1st mixing circuit (HT): Kvs = 13.3 - V'max[100mbar] = 4.2m³/h - Q'max[20K] = 98kW - leakage rate < 0.1% - 2nd mixing circuit (NT): Kvs = 12.9 • V'max[100mbar] = 4.1m³/h • Q'max[10K] = 48kW • Leakage rate < 0,1%

Baunach